RSS 4 projects tagged "data center"

No download Website Updated 14 Apr 2014 openDCIM

Screenshot
Pop 131.59
Vit 50.08

openDCIM is a Web-based data center inventory application which allows you to manage capacity and track assets throughout multiple data centers. There are some graphical elements to the system, but overall, the system is designed for keyboard-friendly (rather than click-happy) use. It is written in PHP and utilizes a MySQL backend for ease of deployment on nearly any LAMP-based build.

Download Website Updated 29 Nov 2011 Sequencer

Screenshot
Pop 30.72
Vit 29.47

Sequencer is an engine used by system administrators for the computation and execution of sequences of actions over hardware or software. It can ping various devices in parallel, power on your whole cluster, or generate an Emergency PowerOff (EPO) script for your data center or cluster. It takes into account various dependencies (power off nodes before switches, clients before server), deals with failures kindly, and is very efficient (>4000 nodes in less than 10 minutes).

No download Website Updated 24 Dec 2013 ITDB

Screenshot
Pop 280.40
Vit 14.44

ITDB is a Web-based tool used to store information about assets found in office environments, with a focus on IT assets, but not limited to such. It will help you keep track of hardware, software, relationships between assets, invoices, locations, contracts, people, and rack layouts. It can also print labels for all assets.

Download No website Updated 09 Oct 2010 Outlets

Screenshot
Pop 24.17
Vit 1.00

Outlets is an AJAX-enabled centralized power distribution unit (PDU) manager. It has has been tested on APC and Tripplite units with SNMP functionality, but can work with other units given proper configuration. To change the name of an outlet, simply click its name and enter the new value. Press Enter to confirm or Esc to cancel. Outlets can be switched on or off by clicking the status and selecting the desired status from the drop down, then clicking OK. Changes are written via SNMP, thus each PDU must have an accessible SNMP write community. Outlets can use a standard LAMP setup, though it does not require or use MySQL. In addition, it requires the php5-snmp module. All PDUs must support SNMP v1 and be set up to allow the IP of the machine Outlets is hosted on to access SNMP. Some Tripplite units exhibit a behavior where they do not properly confirm SNMP writes and stop responding to requests for about 60 seconds after SNMP writes. They can still be managed (it's just a bit wonky), but the APC units work flawlessly.